PAC Database - Detailed Chemical Data

Chemical Identity
Chemical CAS# UN# Health Code Numbers
Nitrosotoluene, 2-; (o-Nitrosotoluene) 611-23-4
15.01
11.01
15.02
3.10
3.09
3.01




Formula Synonyms
C7H7NO
Physical Properties
Mol Wt State MP (°C) BP (°C) VP (Hg) VP (°C) SG LEL (ppm)
121.15 S 72.5
PAC Values
PAC Values (Original Units: mg/m3)
PAC-1 PAC-2 PAC-3
12 130 790
Converted PAC Values (ppm)
PAC-1 PAC-2 PAC-3
2.4 26 160
Technical Basis
A review of available sources did not identify exposure limits or acute toxicity data for this chemical. Reported GHS health hazard ratings (H315 and H319, Category 2; H335, Category 3; H302, H312, and H332; Category 4) and NFPA and HMIS=2 indicate a mid-level health hazard, approximately equivalent to an HHR=2. Considering this, analysts assumed an HHR=2 as the TEEL-3 basis (Section 3.4.5). TEEL-2 and TEEL-1 were derived according to Table 3.5.
• PAC-1 = TEEL-1 = TEEL-2/11
• PAC-2 = TEEL-2 = TEEL-3/6
• PAC-3 = TEEL-3 = HHR=2
This review generated PAC values consistent with Rev. 29A.
References
Chemical information and GHS health hazard ratings retrieved from: https://pubchem.ncbi.nlm.nih.gov/compound/2-Nitrosotoluene and https://www.sigmaaldrich.com/US/en/sds/aldrich/n26407?userType=anonymous
Sigma Aldrich SDS; NFPA=2, HMIS=2: https://www.chemblink.com/MSDS/MSDSFiles/611-23-4Sigma-Aldrich.pdf
Search Again